Contents14 sections
This guide was first published in German on handgetestet.de.
The cable doesn’t reach the car, so you add a second one? Don’t. Manufacturers‘ manuals rule out extensions, and the technical guideline of the German standards and industry associations advises against them. The clean answer is a single, longer cable, for an 11 kW car for example the Lapp Standard Type 2 charging cable at 10 meters. It weighs a little over three kilograms, considerably less than the 22 kW version.
This guide covers Mode 3 cables between a charging station or wallbox and the car. What sets Mode 2 apart from Mode 3 is explained in our charging cable guide (in German).
Can you extend a Type 2 cable?
In practice, no. The freely available benchmark is the German technical guideline on charging infrastructure (Technischer Leitfaden Ladeinfrastruktur) published by DKE, VDE FNN, BDEW, ZVEH, ZVEI and VDA. For safety reasons, it advises against extension leads, power strips, cable reels and travel adapters. For planning purposes, it states that the vehicle must be connectable without an extension or reel, which is why the station belongs right next to the parking space.
The manufacturers get more specific. Lapp writes in the manual for its Mode 3 cables: no adapters, no transition adapters, no extension cables. HARTING considers it improper use if the cable serves as an extension or is used together with an extension lead. NRGkick also prohibits additional cables on the vehicle side of its mobile charger.
That leaves the legal question. We could not reliably establish an explicit ban for private users. For you, something else matters. According to Lapp, in case of improper use the operator is liable, not the manufacturer. If you connect two cables, you leave the approved use of both manufacturers and carry the risk alone.
You will still find adapters and ready-made extensions in stores. Sold does not mean approved. Check the manuals for your car and your wallbox before you even consider something like that. And the same goes for the household outlet: the cable reel (in German) stays with the lawn mower.
When a longer cable really helps
At charging stations and wallboxes with a Type 2 socket, you simply swap the cable. No electrician, no approval question. Typical cases are a charging flap on the wrong side, a parking space opposite the socket, or a charging station behind a parked van. According to the ADAC, Germany’s largest automobile club, how long it needs to be depends on where the wallbox is mounted, whether you park nose-in or reverse in, and where the flap is.
It’s a different story with a wallbox that has a permanently attached cable. No accessory helps here. First check whether reversing into the space solves the problem. If not, a licensed electrician can clarify whether the box can be moved or swapped for a model with a socket or a longer cable. The available designs are covered in the wallbox guide.
What length makes sense?
Measure instead of guessing. Lay a string from the socket to the charging flap, once parked nose-in and once reversed in, routing it the way the cable will later lie. Then add a little reserve.
The ADAC recommends seven or eight meters for all situations. Ten meters is the exception for parking spaces where that demonstrably isn’t enough. More length means more weight in the trunk and more wet cable on the ground. According to the ADAC, a brightly colored cable is less likely to become a trip hazard, which is no minor point next to sidewalks.
What cross-section does a long cable need?
This is where the real buying decision lies. At Lapp, the 11 kW cable has five conductors of 2.5 mm², the 22 kW cable five conductors of 6 mm². Over ten meters, that means 3.01 versus 5.24 kilograms. According to the ADAC, a cable gets thicker, heavier, more expensive and more unwieldy as the current rating rises.
Does the thick cable do anything for an 11 kW car? No. No more current flows than the onboard charger accepts. Losses don’t argue against it either: by our rough calculation, at 16 amps three-phase over ten meters and 2.5 mm², we arrive at around 55 watts, about half a percent of 11 kW. With 6 mm² it would be around 22 watts. In the comparison by the Touring Club Switzerland, reported on by the ADAC, the cables differed by less than one percent in efficiency.
So only buy the 32-amp version if your car accepts 22 kW or your next one is supposed to. Otherwise you’re hauling a good two kilograms of copper and sheathing for nothing.
Six cables for the longer distance
| Model | Current and power | Length and weight | Conductors | Best for |
|---|---|---|---|---|
| Lapp Standard Type 2 charging cable 11 kW 10 m | 20 A, 3-phase, 11 kW | 10 m, 3.01 kg | 5G2.5 | 11 kW car, long way to the socket |
| Lapp Standard Type 2 charging cable 11 kW 7 m | 20 A, 3-phase, 11 kW | 7 m, 2.30 kg | 5G2.5 | Everyday cable for charging station and wallbox |
| Lapp Standard Type 2 charging cable 22 kW 10 m | 32 A, 3-phase, 22 kW | 10 m, 5.24 kg | 5G6 | 22 kW car with a long way to go |
| Mennekes 36247 | 32 A, 3-phase, 22 kW | 7.5 m, 4.43 kg | 5G6 | 22 kW at medium length |
| Harting EVC0107 | 20 A, 3-phase, 11 kW, according to the Amazon listing | 10 m, weight not stated | not stated | Alternative to Lapp’s 10 m cable |
| EVDANCE Type 2 charging cable | according to the seller 22 kW or 11 kW | according to the seller 6.1 m, up to 10 m on Amazon | not stated | only after checking the manual and test marks |
Lapp Standard Type 2 charging cable 11 kW 10 m
The sensible choice for most long distances. According to Lapp, rated up to 20 amps three-phase, protection class IP55 with longitudinal water tightness, and approved from minus 40 to plus 50 degrees Celsius. It currently can’t be ordered in the manufacturer’s shop; Lapp refers buyers to Amazon. The cable also comes in orange, which stands out in a parking lot. It’s not for 22 kW cars.
Lapp Standard Type 2 charging cable 11 kW 7 m
About 700 grams lighter than the 10-meter version and close to the ADAC recommendation. If your string reaches, take this one.
Lapp Standard Type 2 charging cable 22 kW 10 m
Technically the big solution, in everyday use a hefty lump. It only makes sense if the car really uses the 22 kW. 5.24 kilograms have to come out of the trunk and go back in at every stop.
Mennekes 36247
A second brand, same current class: 32 amps, 22 kW, 7.5 meters, conductors 5G6. Protection class IP44 according to the data sheet, usable from minus 40 to plus 50 degrees Celsius. At 4.43 kilograms, it suits owners of 22 kW cars who find ten meters too much. We also mention it as a travel cable in the charging cable guide (in German).
Harting EVC0107
Ten meters, 20 amps, 11 kW according to the Amazon listing. We don’t have a data sheet for this exact cable, so there’s no recommendation here. A 5-meter coiled cable from Harting was rated „highly recommended“ in the Touring Club Switzerland comparison, but that says only so much about this version.
EVDANCE Type 2 charging cable
The seller lists the cables in its shop under the category „Extension Cable“. According to its own information, they are nevertheless regular Type 2 to Type 2 cables with 22 or 11 kW, about 6.1 meters long according to the seller, and also available with 8 and 10 meters on Amazon. Don’t connect a cable like this behind an existing one. Look at the manual and test marks before buying, because we have neither a data sheet nor a declaration of conformity. The seller hasn’t told us the cross-section or weight. For unknown brands, the ADAC advises checking the manufacturer details on the rating plate and the declaration of conformity. On Trustpilot, EVDANCE stood at 3.9 out of 5 points from 37 reviews in November 2026, 24 percent of them with one star, mainly because of shipping and service.
Handling long cables properly
Long cables suffer more often. The guideline requires a check for visible damage before every use; damaged cables and plugs stay out of service. Lapp prohibits driving over the cable and advises coiling it without kinks and fitting the protective cap. HARTING rules out knotted cables while charging. Clean only when unplugged, with a dry cloth.
How we would decide
- The cable is too short and the wallbox has a socket: buy a longer cable, not an extension.
- Car with 11 kW, the string measures up to 7 meters: Lapp 11 kW 7 m.
- Car with 11 kW, the parking space needs more: Lapp 11 kW 10 m.
- Car with 22 kW: Mennekes 36247, for longer distances Lapp 22 kW 10 m.
- Permanently attached cable too short: ask a licensed electrician, don’t plug anything in between.
Frequently asked questions
Can you extend a Type 2 charging cable?
In practice, no. Lapp rules out adapters and extension cables in its manual, and HARTING considers it improper use. According to Lapp, in case of improper use the operator is liable, not the manufacturer. If you connect two cables, you carry the risk alone.
How long should a Type 2 cable be?
The ADAC (Germany's largest automobile club) recommends seven or eight meters; ten meters is the exception for parking spaces where that is not enough. Measure instead of guessing: lay a string from the socket to the charging flap, once parked nose-in and once reversed in, then add a little reserve.
Does an 11 kW car need a 22 kW cable?
No. No more current flows than the onboard charger accepts. At Lapp, the 11 kW cable weighs 3.01 kilograms at ten meters, the 22 kW cable 5.24. The 32-amp version only pays off if your car accepts 22 kW or your next one is supposed to.
What if the wallbox cable is permanently attached and too short?
No accessory helps here. First check whether reversing into the space solves the problem. If not, a licensed electrician can clarify whether the box can be moved or swapped for a model with a socket or a longer cable. Do not plug anything in between.
Which long Type 2 cable suits a 22 kW car?
The Mennekes 36247 with 7.5 meters, 32 amps and 4.43 kilograms, for owners who find ten meters too much. For longer distances, the Lapp Standard Type 2 charging cable 22 kW at 10 meters, although at 5.24 kilograms it is heavy for everyday use.
How should you handle a long charging cable?
Check it for visible damage before every use; damaged cables and plugs stay out of service. Lapp prohibits driving over the cable and advises coiling it without kinks and fitting the protective cap. Clean it only when unplugged, with a dry cloth.
Sources
- DKE, VDE FNN, BDEW, ZVEH, ZVEI, VDA: Technical guideline on charging infrastructure for electric mobility, version 4.1 (PDF, German)
- Lapp Mobility: Operating manual charging cable Mode3 2.0 (PDF)
- Lapp Mobility: Data sheet Standard charging cable (PDF)
- Lapp Mobility: Standard Type 2 charging cable (11 kW) 10 m
- Lapp Mobility: Standard Type 2 charging cable (22 kW) 10 m
- HARTING: Operating manual Mode 3 Type 2 charging cable assembly
- NRGkick: Operating manual (PDF)
- Mennekes: Product data sheet 36247 (PDF)
- ADAC: Charging cables and plug types
- ADAC: Mobile wallboxes compared (July 2024)
- Trustpilot: Reviews of EVDANCE
Where to buy
- Lapp Standard Ladekabel Typ 2 11 kW 10 mCheck price at Amazon.de
- Lapp Standard Ladekabel Typ 2 11 kW 7 mCheck price at Amazon.de
- Lapp Standard Ladekabel Typ 2 22 kW 10 mCheck price at Amazon.de
- Mennekes 36247Check price at Amazon.de
- Harting EVC0107Check price at Amazon.de
- EVDANCE Typ-2-LadekabelView at EVDANCE