Black Friday Woche ab 19.11.: unsere Wahl je Ratgeber
Independent buying adviceEvery claim with a sourceNo paid verdictsIn 36 countries1,734 guides and reviews in German How we test
handgetestet
This page in 6 more languages

DeutschNederlandsFrançaisItalianoEspañolPolski

Buying Network Cable 2026: Cat 6a or Cat 7, Flat, Wall Jacks

Buying a network cable: why Cat 7 with RJ45 performs like Cat 6a, when a flat cable is enough, and which installation cable belongs in the wall with which jack.

handgetestet editorial team · Updated November 17, 2026
Contents14 sections

This guide was first published in German on handgetestet.de.

The package says Cat 7, but in operation the cable delivers Cat 6a. That is not a scam; it comes down to the connector. For patch cables between router, switch and device, we therefore recommend a double-shielded Cat 6a cable such as the Hama 00200682, and inside the wall, solid Cat 7 installation cable with copper conductors and fire rating Cca, terminated on a shielded Cat 6a wall jack. A home does not need more than that in 2026.

Cat 6a or Cat 7: what the connector makes of it

With RJ45 connectors, 500 MHz is the limit. DeleyCON states this openly in the specs for its flat cables: the bulk cable handles 600 MHz, but with RJ45 connectors it is no more than 500 MHz, which means Cat 6a. In practice, a factory-made „Cat 7 patch cable“ is therefore a Cat 6a cable with a thicker jacket. That is not bad. It just brings no advantage your network could measure.

With installation cable, the math is different. Here Cat 7 has a solid reason: the cable stays in the wall for twenty years, and while the jacks at either end can be replaced, the cable cannot. The link itself is still only as fast as its weakest part, so with a Cat 6a jack it is Class EA.

How fast does it need to be?

For gigabit, Cat 5e is already enough over 100 meters. Things get interesting at 10 gigabit, which NAS devices and newer routers now offer. On this point, the cable manufacturer ICC refers to the TIA guideline TSB-155-A: over installed Cat 6, 10GBASE-T runs reliably up to 37 meters, and between 37 and 55 meters it depends on crosstalk from neighboring cables. Cat 6a carries 10 gigabit over the full 100 meters. From the basement to the attic of a single-family home, the cable route easily adds up to 30 to 40 meters, and that is exactly where Cat 6 becomes a gamble.

Whether your devices can actually make use of that speed is decided by the switch. Which switches handle 2.5 or 10 gigabit is covered in our guide to network switches (in German). And where a cable simply cannot go, a powerline connection over the electrical wiring is a better help than a cable running across the hallway.

Flat, round, shielded: three questions for the jacket

Flat cables fit under doors and behind baseboards. According to the manufacturer, the DeleyCON flat cable measures 1.5 mm in height and 6 mm in width. In return, flat designs give up part of the shielding: Hama lists its flat Cat 6a cable as U/UTP, meaning completely unshielded, and DeleyCON lists its own as U/FTP with a foil shield around the pairs. In the living room between router and TV, that rarely causes problems. Next to a bundle of power cables under the desk, it is a different story.

Round and double-shielded, S/FTP for short, means foil around each wire pair and a braid around everything. A cable like that is stiffer. It is harder to lay into tight corners but shields against interference better. For fixed runs in the home office or equipment cabinet, this is the design we use.

Length: measure along the route, not in a straight line

Measure where the cable will actually lie. That means along the baseboard, around the door frame, up behind the cabinet. Add half a meter of slack. A cable that is too short pulls on the connector, and the latch eventually breaks off. Ten meters of excess length is no solution either, because the rest ends up as a tangle behind the TV.

Cable in the wall: fire rating and real copper

As soon as a cable is permanently installed in a building, it is a construction product. Since July 1, 2017, such cables must carry CE marking and a declaration of performance under the European Construction Products Regulation, as the German electrical industry association ZVEI summarizes it. In Germany, at least fire rating Eca is mandatory. For buildings with high safety requirements such as offices, the ZVEI recommends Class Cca, and for hospitals, daycare centers and escape routes B2ca. The association has no separate recommendation for residential homes. We would still choose at least Cca, because the cable runs through the stairwell and hallway.

Three letters can easily be confused. „Cca“ is the fire rating. „CCA“ stands for copper clad aluminium, meaning copper-coated aluminum wire. According to a technical note from the Fibreoptic Industry Association, network cables with such conductors generally do not meet the CENELEC, TIA and ISO/IEC standards. DeleyCON specifically points out this difference on its product page. So check the data sheet for the word copper, and specifically for the conductor, not just the jacket.

Installation cable is solid and is not crimped; instead, it is punched down onto LSA terminals in the jack. That requires a punch-down tool; Telegärtner names an LSA-Plus tool in its instructions. And a little patience.

Six cables and jacks side by side

ModelType and categoryShielding and conductorBest for
Hama 00200682 (5 m)Round patch cable, Cat 6a, 500 MHzS/FTP, double-shielded, PVC jacketfixed runs to router, switch, NAS
Hama 00200685 (5 m)Flat patch cable, Cat 6a, 500 MHzU/UTP, unshielded, PVC jacketunder rugs and doors, living room
DeleyCON flat cable with Cat 7 bulk cableFlat patch cable, Cat 6a with RJ45U/FTP, halogen-free, 1.5 × 6 mmseveral short, flat connections
DeleyCON Cat.7 installation cable (MK4011–MK4015)Installation cable, Cat 7, 1000 MHzS/FTP PiMF, solid copper AWG 23, Ccapermanently wiring an apartment or house
DeleyCON Cat6a wall jack 2× RJ45Flush-mounted jack, Cat 6a, 500 MHzshielded, T568A and B labeledgetting started with home cabling
Telegärtner AMJ45 8/8 K UP/50 Cat.6AFlush-mounted jack, Cat 6A, Class EAdie-cast zinc shield housing, LSA-Plushome cabling built to last decades

Hama Netzwerkkabel CAT-6a S/FTP

Our standard cable for everything that stays in place. Hama specifies Cat 6a at 500 MHz, double S/FTP shielding, a PVC jacket and a strain-relief boot at the connector; item number 00200682 stands for the black 5-meter version.

Hama Netzwerkkabel CAT-6a U/UTP flat

The same speed, but flat and unshielded. Hama describes it as a ribbon cable for laying under rugs and into corners, with a slim connector for tight ports. For the route from the router under the living room door, it works well. Next to power supplies and power strips, we would rather reach for the shielded version.

DeleyCON flat cable with Cat 7 bulk cable

The example of an honest data sheet. DeleyCON sells the flat cable in sets of five and ten, specifies U/FTP shielding, a halogen-free jacket and T568B wiring. Right next to that, it states that only 500 MHz is possible with RJ45 connectors. As the transmission rate, the manufacturer lists gigabit. If you want to connect several devices on a desk with flat cables, this gives you plenty of room.

DeleyCON Cat.7 installation cable

The cable for the wall. According to the manufacturer, it has four wire pairs with solid copper conductors to AWG 23 and 0.55 mm diameter, a foil shield per pair plus an overall braided shield, a halogen-free jacket and fire rating Cca s1 d1 a1 under EN 50575. Lengths range from 10 to 100 meters. DeleyCON explicitly points out that it is intended only for LSA connections and is not crimped.

DeleyCON Cat6a wall jack 2× RJ45

A shielded flush-mounted jack with two ports, 500 MHz and 10 gigabit according to the manufacturer. The cable entry can be rotated in four steps, the terminals are color-coded for T568A and T568B, and installation instructions are included. For a first jack in the home office, that is enough.

Telegärtner AMJ45 8/8 K UP/50 Cat.6A

A jack with a detailed data sheet. Telegärtner specifies Category 6A to ISO/IEC 11801 and DIN EN 50173-1, suitability for 10-gigabit Ethernet to IEEE 802.3an and for PoE up to 802.3bt. The shield housing is die-cast zinc, and the LSA-Plus terminals accept solid conductors from AWG 26 to AWG 22, so the DeleyCON installation cable fits. Add to that at least 750 mating cycles and a cable entry in eight 45-degree steps. Dust covers are only available separately.

How we would decide

  • Router, switch and NAS in the same room: Hama Cat 6a S/FTP in the right length. Cat 7 brings nothing here.
  • TV or console behind the door: the flat Hama cable, as long as it does not run next to power cables.
  • Several desk devices: the DeleyCON flat set, if gigabit is enough.
  • New build or renovation: Cat 7 installation cable with fire rating Cca and copper conductors, plus shielded Cat 6a jacks. If the installation is meant to last twenty years, we would choose the Telegärtner jack.

Frequently asked questions

Is a Cat 7 patch cable worth it?

Hardly. With RJ45 connectors, 500 MHz is the maximum, which means Cat 6a. In practice, a factory-made Cat 7 patch cable is a Cat 6a cable with a thicker jacket. For installation cable in the wall, on the other hand, Cat 7 makes sense, because it stays there for decades and cannot be replaced.

Is Cat 6 enough for 10 gigabit?

Only over short runs. According to the TIA guideline TSB-155-A, 10GBASE-T runs reliably over installed Cat 6 up to 37 meters; beyond that, it depends on crosstalk. Cat 6a carries 10 gigabit over the full 100 meters. For gigabit, Cat 5e is already enough.

Flat cable or round network cable?

Flat cables fit under doors and behind baseboards but give up part of the shielding; the flat Hama cable is completely unshielded. Round S/FTP cables are stiffer but shield against interference better. Next to power cables and power supplies, the shielded version is the better choice.

Which fire rating does an installation cable need?

In Germany, at least Eca is mandatory. The German electrical industry association ZVEI recommends Cca for buildings with high safety requirements. There is no separate recommendation for residential homes; since the cable runs through the stairwell and hallway, at least Cca still makes sense.

What is the difference between Cca and CCA?

Cca is the fire rating. CCA stands for copper clad aluminium, meaning copper-coated aluminum wire. According to the Fibreoptic Industry Association, such cables generally do not meet the relevant standards. Check the data sheet for the word copper for the conductor.

How long should a network cable be?

Measure along the route the cable will actually take, meaning along the baseboard and around the door frame, not in a straight line. Add half a meter of slack. A cable that is too short pulls on the connector; a lot of excess length ends up as a tangle behind the TV.

Sources

Where to buy

Shop in:

Sale, delivery, warranty and product safety are the sole responsibility of the respective retailer and manufacturer. All information without guarantee; prices and availability may change.

Links marked as affiliate links earn us a small commission if you buy through them. The price stays the same for you, and our verdict stays independent. As an Amazon Associate we earn from qualifying purchases.