An outlet for the garden is quick to buy and hard to connect, because the work lies in the trench, not in the post. If you need permanent power at a flower bed or on the patio, the plain Steckdosensäule 2-fach Edelstahl (two-socket stainless steel outlet post) from ELV (German retailer) serves you well, connected by a licensed electrician. You can make it smart later with a switching and measuring cable. Everyone else may manage without any digging at all. Which route suits you depends on three questions.
Only need a few hours of power in summer?
Then don’t dig. For a string of lights, a radio or an electric grill, a garden outlet with a ground spike plugged into an existing outdoor outlet is enough. Brennenstuhl offers one with four sockets, self-closing hinged covers and IP44, and explicitly states that it is suitable for permanent outdoor use. For longer distances, there is a version with 10 meters of rubber cable, or you can use a suitable cable reel. If there is a shed in the garden with no connection at all, read our guide to power in the garden shed (in German) first.
Should the power be there permanently?
Pond pump, robotic mower station, garden lighting: here a fixed line is the way to go. That is skilled work governed by regulations.
Under Section 13 of the German Low Voltage Connection Ordinance (Niederspannungsanschlussverordnung, NAV), work on the installation behind the main service fuse may only be carried out by the grid operator or by a company listed in a grid operator’s installer register. A new branch circuit into the garden is part of that. Agree beforehand on what you can take on yourself; usually that is digging the trench.
A cable such as NYY-J goes into the ground, which Helukabel explicitly specifies for laying in soil. How deep it has to lie and how it is protected against spades is determined by the electrician according to the German VDE regulations. Ask about it before you dig the trench, and mention any beds that get dug over every spring. Sketch the route with measurements and keep the drawing.
At the other end, in the distribution board, a residual current device (RCD) belongs in front of it. Oase, for example, specifies a maximum of 30 milliamperes for its garden equipment. Older installations sometimes lack one, so ask about it right when you request a quote.
The electrician calculates the cross-section from the length and the fusing. If an existing buried cable needs to be extended or repaired, our guide to outdoor cable connectors (in German) will help. And if you only want to power path lights, low voltage is often the simpler route, as explained in the guide to mains-powered garden lighting.
What does IP44 do, and what doesn’t it do?
The 4 in first place stands for protection against foreign objects of one millimeter and larger, the 4 in second place for splashing water from all directions. That covers rain. Standing water, no. The manufacturer of the ELV post rules out spots that flood when it rains, such as hollows, and requires a distance of 0.5 meters from water containers. So the lowest spot in the lawn is out, however practical it would be. IP55, as with ELV’s outdoor outlets, goes a step further and also withstands water jets. The cover only helps as long as it is closed.
Should the outlet switch smartly?
There are two ways to get there. Either a weatherproof inline switch sits in front of the device, which takes minutes. Or the actuator sits permanently in the outlet box, which looks cleaner and is a job for a qualified electrician. For Homematic IP, you need an Access Point or a hub in both cases. The guide controlling garden lighting smartly gives an overview of schedules and outdoor sensors.
Six solutions side by side
| Model | Design | Protection rating | Load according to the manufacturer | Best for |
|---|---|---|---|---|
| Steckdosensäule 2-fach Edelstahl | Fixed post, 23 cm tall, 2 sockets | IP44 | 16 A, 3,680 W | Patio, edge of the yard |
| ELV Set Außensteckdose HmIP-FSI16 | Surface-mounted outlet with actuator (kit) | IP55 (outlet) | 3,680 W for 15 minutes | Large loads, house wall |
| ELV Set Außensteckdose HmIP-FSM | Surface-mounted outlet with measuring actuator (kit) | IP55 (outlet) | 1,150 W | Pump with consumption display |
| Homematic IP Schalt-Mess-Kabel HmIP-PSMCO | Inline switch on the cable | IP44 | 10 A, 2.3 kW | Retrofitting on a fixed outlet |
| LEDVANCE SMART+ WiFi Outdoor Plug | Wi-Fi plug adapter, ground spike | IP44 | 16 A, 3,680 W | Smart without a hub |
| Brennenstuhl Gartensteckdose 4-fach | Ground spike, 1.4 m rubber cable | IP44 | 16 A | Mobile, no digging |
Steckdosensäule 2-fach Edelstahl
Small, rustproof, with two hinged covers and a terminal block inside. The post comes from Die Bold and is intended for the home garden, not for construction sites or commercial use. There are two points you should know before buying. It is screwed down; no ground spike is included. So it needs a solid surface such as a concrete base or a wall and may only stand upright. In addition, the instructions specify H07RN-F 3G 1.5 mm² or a cable of the same diameter for the connection. Whether an NYY-J fits directly or a transition in a junction box is needed should be clarified by the electrician in advance. At 23 centimeters, it is low and disappears in long grass.
ELV Set Außensteckdose HmIP-FSI16
A Berker surface-mounted outlet box with a Schuko (German grounded) socket insert and mounting plate, with a Homematic IP switch actuator inside. The data sheet allows 16 amperes for 15 minutes; ELV also states 14 amperes and 3,220 watts as switching values. That is interesting for patio heaters. The actuator is a kit, however: according to the assembly instructions, a soldering iron, soldering experience and a qualified electrician are prerequisites. Without someone who can do that, this set is the wrong choice.
ELV Set Außensteckdose HmIP-FSM
The same outlet with a measuring actuator for up to 1,150 watts and 5 amperes. So you can see what the pond pump actually draws. The limit is too low for heaters. This actuator also comes as a kit; according to the assembly instructions, assembly and installation belong in the hands of qualified professionals.
Homematic IP Schalt-Mess-Kabel HmIP-PSMCO
The cable goes between the outlet and the device and measures consumption along the way. You don’t have to install anything. According to ELV, it is intended for garden lighting, irrigation and similar uses up to 2.3 kilowatts with resistive loads. The instructions only allow operation on permanently installed grounded outlets, not on power strips or extension cords. So it works on the post, but not on the ground spike solution. It is not approved for heating applications.
LEDVANCE SMART+ WiFi Outdoor Plug
If you don’t have a hub, take this plug with a 1.5-meter cable and ground spike holder. According to the manufacturer, it switches up to 3,680 watts, measures consumption and uses 2.4 GHz Wi-Fi. That is exactly its weak point: the network still has to reach the end of the garden, and remote access runs through the cloud.
Brennenstuhl Gartensteckdose 4-fach
The solution without a tradesperson. Four sockets on a spike, H07RN-F rubber cable, plugged into the existing outdoor outlet. In the fall, you simply pull it out again. The cable does remain visible, of course, and the lawn mower has to go around it.
Which route suits you?
- Barbecue evening and string lights: Brennenstuhl Gartensteckdose.
- Permanent power on the patio or at the edge of the yard: outlet post with buried cable from a licensed electrician.
- Post already in place, lights should switch on a schedule: HmIP-PSMCO.
- No smart home system, Wi-Fi reaches into the garden: LEDVANCE Outdoor Plug.
- Fixed to the house wall, large load, electrician available: set with HmIP-FSI16.
Building permits, power connection and wood-burning stove are covered in the guide to the barrel sauna in the garden.
If you are planning a permanent tub, use the guide to the hard-shell hot tub to check the floor load and the power line.
We have tried out an outlet post with a ground spike ourselves: our review of the MONZANA garden outlet with four sockets covers what convinced us and where there were scratches.
Frequently asked questions
Can I connect a garden outlet myself?
Not a new branch circuit into the garden. Under Section 13 of the German Low Voltage Connection Ordinance (NAV), only the grid operator or a company listed in an installer register may work behind the main service fuse. Agree beforehand on what you can do yourself; usually that is digging the trench.
Which cable goes into the ground?
A cable such as NYY-J, which Helukabel explicitly specifies for laying in the ground. The electrician determines the depth and the protection against spades according to the German VDE regulations and calculates the cross-section from length and fusing. Sketch the route with measurements and keep the drawing.
What does IP44 mean for an outdoor outlet?
The first 4 stands for protection against foreign objects of one millimeter and larger, the second for splashing water from all directions. That covers rain, but not standing water. Hollows that flood when it rains are therefore ruled out. IP55 additionally withstands water jets.
Does a garden outlet need a residual current device?
In the distribution board, a residual current device (RCD) belongs in front of the garden circuit. Oase, for example, specifies a maximum of 30 milliamperes for its garden equipment. Older installations sometimes lack one, so ask about it right when you request a quote.
How do you make an outdoor outlet smart?
Either with a weatherproof inline switch in front of the device, such as the HmIP-PSMCO switching and measuring cable on a permanently installed outlet, or with an actuator fixed inside the outlet box, installed by a qualified electrician. Without a hub, the LEDVANCE Outdoor Plug switches via Wi-Fi; remote access then runs through the cloud.
What should you watch for with the stainless steel outlet post?
It is screwed down, no ground spike is included, and it needs a solid surface such as a concrete base or a wall. The instructions specify H07RN-F 3G 1.5 mm² for the connection; the electrician should clarify in advance whether an NYY-J fits directly. At 23 centimeters tall, it disappears in long grass.
Sources
- German Low Voltage Connection Ordinance (NAV), Section 13
- Helukabel: NYY buried cable data sheet (PDF)
- Wikipedia: Buried cable (laying depth according to DIN VDE 0100-520)
- Wikipedia: Residual current device (DIN VDE 0100-410)
- Initiative Elektro+: Protection against electric shock
- Wikipedia: IP protection rating
- ELV: Steckdosensäule 2-fach (retailer information)
- Die Bold: Safety instructions for the outlet post (PDF)
- ELV: Set Außensteckdose HmIP-FSI16 (retailer information)
- eQ-3: HmIP-FSI16 data sheet (PDF)
- ELV: HmIP-FSI16 assembly instructions (PDF)
- ELV: Set Außensteckdose HmIP-FSM (retailer information)
- ELV: HmIP-FSM assembly instructions (PDF)
- ELV: Schalt-Mess-Kabel außen HmIP-PSMCO (retailer information)
- eQ-3: HmIP-PSMCO instructions (PDF)
- ELV: LEDVANCE SMART+ WiFi Outdoor Plug (retailer information)
- LEDVANCE: Outdoor Plug product data sheet (PDF)
- Brennenstuhl: Gartensteckdose mit Erdspieß 4-fach
Where to buy
- Steckdosensäule 2-fach EdelstahlView at ELVAvailable in Germany: ELV
- ELV Set Außensteckdose HmIP-FSI16View at ELVAvailable in Germany: ELV
- ELV Set Außensteckdose HmIP-FSMView at ELVAvailable in Germany: ELV
- Homematic IP Schalt-Mess-Kabel HmIP-PSMCOView at ELVAvailable in Germany: ELVCheck price at Amazon.deAvailable in Germany: Amazon.de
- LEDVANCE SMART+ WiFi Outdoor PlugView at ELVAvailable in Germany: ELVCheck price at Amazon.deAvailable in Germany: Amazon.de
- Brennenstuhl Gartensteckdose 4-fachCheck price at Amazon.deAvailable in Germany: Amazon.de