Contents11 sections
This guide was first published in German on handgetestet.de.
An alarm dialer calls or sends a text message as soon as a signal is present at one of its inputs. No router, no app cloud, no Wi-Fi. For the vacation home without internet, the heating system in your parents‘ basement or the sump pit, this is often the most robust solution. If you are buying now, however, look for LTE: the network operators in Germany are shutting down 2G in 2028. Our recommendation for most cases is therefore the Teltonika TRB141 LTE gateway. The ELV GTW-20 remains an option for a narrow range of uses.
First, the question of the network
Many alarm dialers only transmit on the old GSM network. The GTW-20 is one of them; ELV explicitly states that it does not support 3G, 4G and 5G. According to the Verbraucherzentrale (German consumer advice center, as of October 2026), Telekom plans to shut down 2G on June 30, 2028, and O2 in the second half of 2028. Vodafone will discontinue 2G from September 2028 but keep it running until the end of 2030 for critical applications such as older alarm systems. Whether a private SIM in an alarm dialer counts among them, Vodafone does not say there.
So expect just under two years on the mobile network. After that, the only option left for the GTW-20 is an analog phone line.
Which type are you?
You have an alarm system with a dialer output and an analog line. Then the GTW-20 is still a good fit. According to ELV, it dials via landline or GSM, including as an extension, and tries again via the landline if a number does not get through on the mobile network. That way, it survives the 2G shutdown as long as the analog line remains.
You want a fault reported: heating, pump, frost. Here, an LTE gateway with inputs is enough. Many heating systems have a fault signal contact, which is described in their manual. A water leak detector with a relay output or a float switch in the pit closes a contact in just the same way. The Teltonika TRB141 evaluates such potential-free contacts directly.
You want to secure the vacation home completely. Then a single alarm dialer is not enough. An alarm control panel with LTE, wireless detectors and a backup battery is the better basis. What matters there is covered in our guide Buying an alarm system.
Five devices for alerts via mobile network
| Model | Network | Inputs / power | Best for |
|---|---|---|---|
| Teltonika TRB141 | LTE Cat 1, 3G, 2G | 2 inputs dry or wet, 2 relays, 1-Wire / 9 to 30 V DC | Heating, pump, frost monitor |
| ELV GSM-Telefonwählgerät GTW-20 | 2G only, plus analog landline | 4 voltage inputs, 4 outputs / 12 V DC | Existing alarm system with analog line |
| Teltonika TRB140 | LTE Cat 4, 3G, 2G | configurable input/output, Gigabit LAN / 9 to 30 V DC | One signal plus internet on site |
| ELDES ESIM484 | LTE, GSM | 10 wired zones, 64 wireless devices, 8 temperature sensors / 12 V backup battery | Alarm system with wired detectors |
| Ajax Hub 2 (4G) Jeweller | LTE, 3G, 2G, Ethernet | Wireless detectors / battery up to 15 hours | Wireless alarm system with app |
Teltonika TRB141
This small industrial gateway transmits on the LTE network and has exactly the connections a fault alert needs. According to Teltonika, the two digital inputs detect a dry contact switching to ground or an applied voltage. On top of that come two relays, an analog input up to 30 volts and a 1-Wire connection for temperature sensors. With the Event Juggler rule function, you set it to send out a text message when an input signal comes in. Operation is the harder part: setup is done through a web interface for technicians, not a colorful app. If that puts you off, get some help.
ELV GSM-Telefonwählgerät GTW-20
The GTW-20 is a classic alarm dialer with a display and keypad. It stores 20 phone numbers, ten for SMS and ten for voice messages, plus two custom messages. It is triggered when +12 volts are present at input 1 or 2, or -12 volts at input 3 or 4, for at least 3 seconds. Whoever picks up stops the alarm chain with „00“; it also works via SMS. Four outputs can be switched via SMS. A power supply is not included, and the device belongs in dry indoor rooms (IP20). Change the factory password 1234 immediately.
Teltonika TRB140
The sibling of the TRB141 brings LTE Cat 4 and a Gigabit network port, but only one configurable input/output. A level of 8 volts or more counts as „on“. That fits if a computer or camera needs to go online at the vacation home anyway and only a single alert is needed. For several sources of faults, the TRB141 is the better choice.
ELDES ESIM484
A full-fledged alarm control panel with an LTE modem, ten wired zones on the board, four switching outputs and room for up to eight temperature sensors. It reports via SMS and call. ELDES estimates 100 to 5,000 text messages a month depending on use, which matters when choosing a plan. A 12-volt backup battery with 1.3 to 7 amp-hours bridges power outages. Setup is clearly aimed at professional installers.
Ajax Hub 2 (4G) Jeweller
Ajax takes a different approach. The control panel connects via mobile network and Ethernet, and the power supply and backup battery are built in. According to Ajax, the battery lasts up to 15 hours when Ethernet and Wi-Fi are switched off. Alerts arrive via the app, and for setup, the panel needs power and internet once. If you expect a classic phone call without a smartphone app, this is not for you.
The right SIM card
A data plan alone is not enough. For the GTW-20, ELV requires an activated SIM with outgoing calls, call answering, SMS and caller ID, and in the large standard format at that. Disable the PIN prompt on a phone beforehand. Choose the network with the best reception at the installation site, not the one from your own phone contract. Test a basement with a concrete ceiling with your phone before buying. And trigger a test alarm once a month: otherwise, you only notice an alarm dialer that stays silent when it really counts.
One more point that many people forget. Without power, no device reports anything. The GTW-20 and Teltonika run on 12 volts and 9 to 30 volts respectively; a small UPS or a 12-volt power supply with a backup battery keeps them alive during a power outage. For a flooded basement, a suitable submersible pump is also part of the solution; the alarm alone does not pump out any water.
How we would decide
- Heating fault, sump pit or frost in the vacation home: Teltonika TRB141.
- Alarm system with dialer output and analog line, as a bridge until 2028: ELV GSM-Telefonwählgerät GTW-20.
- One alert plus internet for a camera or computer: Teltonika TRB140.
- New alarm system with wired detectors and backup power: ELDES ESIM484.
- Wireless alarm system with app: Ajax Hub 2 (4G) Jeweller.
If you also want a picture from the vacation home, a security camera with a SIM card helps.
Frequently asked questions
Will a GSM alarm dialer still work after the 2G shutdown?
Only via a different route. According to ELV, the ELV GTW-20 supports neither 3G nor 4G or 5G. Telekom plans to shut down 2G on June 30, 2028, and O2 in the second half of 2028. After that, the GTW-20 can only dial via an analog phone line.
How does an alarm dialer report a heating fault?
Many heating systems have a fault signal contact, which is described in their manual. The Teltonika TRB141 evaluates such potential-free contacts directly at its two digital inputs. Using the Event Juggler rule function, you set it to send out a text message when a signal comes in.
Which SIM card does an alarm dialer need?
A data plan alone is not enough. For the GTW-20, ELV requires an activated SIM with outgoing calls, call answering, SMS and caller ID in the large standard format; disable the PIN prompt on a phone beforehand. Choose the network with the strongest reception at the installation site, not the one from your own phone contract.
Is an alarm dialer enough to secure a vacation home?
Not for complete protection. For that, an alarm control panel with LTE, wireless detectors and a backup battery is the better basis, for example the ELDES ESIM484 with wired detectors or the Ajax Hub 2 (4G) Jeweller with an app. A single alarm dialer only reports what is present at its inputs.
What happens to the alarm dialer during a power outage?
Without power, no device reports anything. The GTW-20 and Teltonika run on 12 volts and 9 to 30 volts respectively; a small UPS or a 12-volt power supply with a backup battery keeps them alive. Also trigger a test alarm once a month.
Sources
- ELV: GSM-Telefonwählgerät GTW-20
- ELV: GTW-20 operating manual (PDF)
- Verbraucherzentrale: The 2G shutdown and what it means for consumers
- Teltonika: TRB141
- Teltonika Wiki: TRB141 Input/Output
- Teltonika: TRB140
- Teltonika Wiki: TRB140 Input/Output
- Teltonika Wiki: Event Juggler
- ELDES: ESIM484
- Ajax Systems: Hub 2
Where to buy
- Teltonika TRB141Check price at Amazon.deCheck price at Amazon.co.ukCheck price at Amazon.nlCheck price at Amazon.com.beCheck price at Amazon.frCheck price at Amazon.itCheck price at Amazon.esCheck price at Amazon.plCheck price at Amazon.seAvailable in Germany: Amazon.de
- ELV GSM-Telefonwählgerät GTW-20View at ELVAvailable in Germany: ELV
- Teltonika TRB140View at CoolblueAvailable in Germany: CoolblueCheck price at Amazon.deCheck price at Amazon.co.ukCheck price at Amazon.nlCheck price at Amazon.com.beCheck price at Amazon.frCheck price at Amazon.itCheck price at Amazon.esCheck price at Amazon.plCheck price at Amazon.seAvailable in Germany: Amazon.de
- ELDES ESIM484Check price at Amazon.deCheck price at Amazon.co.ukCheck price at Amazon.nlCheck price at Amazon.com.beCheck price at Amazon.frCheck price at Amazon.itCheck price at Amazon.esCheck price at Amazon.plCheck price at Amazon.seAvailable in Germany: Amazon.de
- Ajax Hub 2 (4G) Jeweller (weiß)Check price at Amazon.deCheck price at Amazon.co.ukCheck price at Amazon.nlCheck price at Amazon.com.beCheck price at Amazon.frCheck price at Amazon.itCheck price at Amazon.esCheck price at Amazon.plCheck price at Amazon.seAvailable in Germany: Amazon.de