Contents14 sections
This guide was first published in German on handgetestet.de.
How many watts does a 20-square-meter room need? Somewhere between 400 and 2,000. That sounds like an evasion, but it is the range that follows from the guide values of the ADAC (German automobile club): 20 to 40 watts per square meter in a well-insulated new build, 60 to 100 watts in a renovated older building. There is no main recommendation here. The only lab measurement we know of comes from Graz University of Technology (TU Graz) and covers a single Könighaus unit from 2022. For a room of around ten square meters, the 600-watt version is still the reference point. But the calculation comes first, because it also decides whether the purchase pays off at all.
How many watts for 10, 20, 30 and 40 square meters?
The list multiplies the ADAC guide values by the floor area, in each case in the order new build (20 to 40 watts per square meter), the ADAC size table, renovated older building (60 to 100 watts). The size table assumes roughly 50 to 70 watts and stops at 30 square meters; the middle value for 40 square meters is our own extrapolation at 60 to 70 watts.
- 10 m²: 200–400 W in a well-insulated new build, 500–700 W according to the ADAC size table, 600–1,000 W in a renovated older building.
- 20 m²: 400–800 W, 1,000–1,400 W, 1,200–2,000 W.
- 30 m²: 600–1,200 W, 1,800–2,000 W, 1,800–3,000 W.
- 40 m²: 800–1,600 W, about 2,400–2,800 W, 2,400–4,000 W.
Unrenovated older buildings are deliberately missing from this list. The ADAC gives no guide value for them, and the Verbraucherzentrale Rheinland-Pfalz (a German consumer advice center) clearly advises against installation in existing buildings.
Why insulation triples the value
In a 2022 master’s thesis at TU Graz, a 96-square-meter single-family house was calculated using a supplier’s sizing software. Well insulated, it came to 2,660 watts; moderately insulated, 6,587 watts; poorly insulated, 7,907 watts. That works out to about 28, 69 and 82 watts per square meter. Same house, same floor plan, three times the output.
The value also varies within a single apartment. In addition to insulation, the ADAC names the number of exterior walls, the windows and the type of room. A corner room with two exterior walls needs more than a room of the same size in the middle, and a bedroom needs less than the living room. So calculate room by room and never with a flat rate for the whole apartment. For proper sizing, the Energie Agentur Steiermark (the energy agency of the Austrian state of Styria) even calls for a heat load calculation for each room. You can find cold spots beforehand with a thermal imaging camera.
Reading manufacturers‘ room size specifications correctly
Könighaus specifies eight to 16 square meters for 600 watts. That corresponds to 37 to 75 watts per square meter, and it is left open which value applies to you. Vasner assumes 50 watts per square meter with „good room insulation,“ and Bosch states five square meters for its 300-watt panel, which is 60 watts. So never go by the upper figure. If you live in a renovated older building, read only the lower value.
One more detail from the lab: in Graz, the 600-watt Könighaus panel drew about 557 watts in steady state. Planning with a few percent of headroom does no harm.
What one room costs per year
The formula is simple: output in kilowatts times hours times electricity price. The ADAC assumes eight hours on 180 days and 37 cents per kilowatt hour. For 20 square meters, that comes to 864 kilowatt hours per year at 30 watts per square meter and 2,016 kilowatt hours at 70 watts. Multiply that by your per-unit rate, and you can see what insulation is worth. Under this assumption, both are upper limits, because a thermostat does not let the panel run continuously at full load. An energy meter shows what your device actually draws.
For a whole apartment, things get serious. Stiftung Warentest (the German consumer testing organization) assumes 8,000 watts for 100 square meters and arrives at 11,680 kilowatt hours per year. At 40 cents per kilowatt hour, in its calculation that costs more than twice as much as gas heating. The verdict: a stopgap. The ADAC also warns of very high running costs when relying on infrared alone.
Five panels and what they can handle on paper
The two right-hand columns are our own calculation, rounded down to whole square meters: 30 watts stands for good insulation, 70 watts for a renovated older building at the low end.
| Model | Area according to manufacturer | At 30 W/m² | At 70 W/m² |
|---|---|---|---|
| Bosch Heat Infrared 4000 P 300 Watt | 5 m² | 10 m² | 4 m² |
| Könighaus Infrarot Wandheizung 600 Watt Thermostat | 8–16 m² | 20 m² | 8 m² |
| Könighaus Infrarot Wandheizung 800 Watt Thermostat | 11–21 m² | 26 m² | 11 m² |
| VASNER Citara M 900 Watt | up to approx. 18 m² | 30 m² | 12 m² |
| Könighaus Infrarot Wandheizung 1200 Watt Smart Thermostat | 18–29 m² | 40 m² | 17 m² |
Bosch Heat Infrared 4000 P 300 Watt
According to Bosch, the smallest unit in this comparison measures 59.2 by 59.2 centimeters, weighs 5.5 kilograms and carries an IP44 protection rating. The size suits a hallway or guest room, but it is not enough to heat a living space. We do not have an independent measurement.
Könighaus Infrarot Wandheizung 600 Watt Thermostat
Ten square meters with good to moderate insulation is this panel’s territory. TU Graz measured six panels, including the 600-watt version of the P series. It reached 105 degrees Celsius on the front and, at 55.3 percent, the highest calculated radiant share on the front side, determined with a thermal imaging camera and not by the standard method. The thermostat version meets the requirement that Könighaus itself states: when permanently mounted, the unit may only be operated with a controller.
Two caveats. The measurement dates from 2022 and covered a single unit. And the back reached 60.5 degrees Celsius, with the drywall behind it at 41.2 degrees. According to the manufacturer, the panel is only suitable for well-insulated rooms or occasional use.
Könighaus Infrarot Wandheizung 800 Watt Thermostat
Same dimensions as the 600-watt version, 60 by 100 centimeters according to Könighaus, but more output on the same surface. That is enough for 20 square meters in a well-insulated new build. In Graz, only the smaller model was measured, and the results cannot simply be transferred.
VASNER Citara M 900 Watt
Metal front, 60 by 120 centimeters, 2.5 centimeters deep, up to about 110 degrees Celsius according to the manufacturer, and with a ten-year warranty. Vasner refers to a test according to DIN EN IEC 60675-3 at TU Dresden, commissioned by the manufacturer itself. No thermostat is included; it comes as a separate item. Suitable controllers are shown in our guide to smart control of electric heaters (in German).
Könighaus Infrarot Wandheizung 1200 Watt Smart Thermostat
The largest size in the range, 60 by 120 centimeters. On paper, it only covers 40 square meters with very good insulation, and even then the output is better spread across several units. In an older building, it tops out at 17 square meters, well below the manufacturer’s upper figure.
From 30 square meters: several panels are better
Infrared heats where it radiates. The Energie Agentur Steiermark therefore recommends several smaller units, especially in long and large rooms, and a distance of no more than 2.5 to 3 meters from the area being heated. The ADAC considers one to two meters favorable. Windows should never be irradiated directly, and tall furniture casts cool shadows. If the system is sized incorrectly, mold can develop in cold corners.
An example for 40 square meters at 70 watts per square meter: 2,800 watts, spread across three panels of 900 watts each plus a little reserve from the existing heating. Mind the circuit; an electrician should check it beforehand.
Is it enough as a primary heating system?
Rarely. According to the ADAC, it only makes economic sense in well-insulated buildings with low heat demand. Legally, under the German Building Modernization Act (Gebäudemodernisierungsgesetz), a new direct electric heating system in existing residential buildings is generally only permitted if the house beats the structural thermal insulation requirements by at least 30 percent. Exceptions include houses with no more than two apartments, one of which is occupied by the owner. According to the ADAC, there is no funding through KfW or BAFA. Which electric heater suits which room is covered in our overview of infrared heaters and fan heaters.
How we would decide
- Home office or guest room of ten square meters, used for a few hours at a time: Könighaus with 600 watts and thermostat.
- 20 square meters in a well-insulated new build: Könighaus with 800 watts, or Vasner with 900 watts if you want to choose the controller yourself.
- Hallway or small side room: Bosch with 300 watts.
- 30 to 40 square meters: two to three panels, not a single-unit solution.
- Unrenovated older building as permanent heating: hands off, insulate first.
Frequently asked questions
How many watts does an infrared heater need for 20 square meters?
Based on the ADAC guide values, 400 to 800 watts in a well-insulated new build, 1,000 to 1,400 watts according to the ADAC size table, and 1,200 to 2,000 watts in a renovated older building. Calculate room by room, because exterior walls, windows and the type of room change the value even within one apartment.
How do I read the manufacturers' room size specifications correctly?
Never go by the upper figure. Könighaus specifies eight to 16 square meters for 600 watts, which corresponds to 37 to 75 watts per square meter. Vasner assumes 50 watts with good room insulation, and Bosch states five square meters for 300 watts. If you live in a renovated older building, read only the lower value.
How much does an infrared heater cost per year?
The formula is output in kilowatts times hours times electricity price. The ADAC assumes eight hours on 180 days. For 20 square meters, that comes to 864 kilowatt hours at 30 watts per square meter and 2,016 at 70 watts. Both are upper limits, because a thermostat does not let the panel run continuously at full load.
Is an infrared heater suitable as a primary heating system?
Rarely. According to the ADAC, it only makes economic sense in well-insulated buildings with low heat demand. Stiftung Warentest (German consumer testing organization) calls it a stopgap. In existing residential buildings, a new direct electric heating system is only permitted to a limited extent under the German Building Modernization Act (Gebäudemodernisierungsgesetz), and according to the ADAC there is no funding through KfW or BAFA.
One large panel or several small ones for large rooms?
Several smaller ones. Infrared heats where it radiates, so the Energie Agentur Steiermark (Styrian energy agency) recommends several devices in long and large rooms, each no more than 2.5 to 3 meters from the area being heated. Windows should never be irradiated directly. Have an electrician check the circuit beforehand.
Is an infrared heater worthwhile in an unrenovated older building?
As a permanent heating system, this guide advises against it: insulate first. The ADAC gives no guide value for unrenovated older buildings, and the Verbraucherzentrale Rheinland-Pfalz (consumer advice center) clearly advises against installation in existing buildings. If the system is sized incorrectly, mold can also develop in cold corners.
Sources
- ADAC: Infrared heating for walls or ceilings
- Stiftung Warentest: Infrared heating, a stopgap with no savings potential
- Verbraucherzentrale Rheinland-Pfalz: Direct electric heating (energy tip, 13.08.2024)
- TU Graz: Metrological analysis of infrared panels (master’s thesis, 2022)
- Energie Agentur Steiermark: Infrared panels guide
- Könighaus: P series wall-mounted infrared heater
- Vasner: Citara M
- Bosch: Infrared heater (metal)
Where to buy
- Könighaus Infrarot Wandheizung 600 Watt ThermostatCheck price at Amazon.deCheck price at Amazon.co.ukCheck price at Amazon.nlCheck price at Amazon.com.beCheck price at Amazon.frCheck price at Amazon.itCheck price at Amazon.esCheck price at Amazon.plCheck price at Amazon.seAvailable in Germany: Amazon.de
- Könighaus Infrarot Wandheizung 800 Watt ThermostatCheck price at Amazon.deCheck price at Amazon.co.ukCheck price at Amazon.nlCheck price at Amazon.com.beCheck price at Amazon.frCheck price at Amazon.itCheck price at Amazon.esCheck price at Amazon.plCheck price at Amazon.seAvailable in Germany: Amazon.de
- Könighaus Infrarot Wandheizung 1200 Watt Smart ThermostatCheck price at Amazon.deCheck price at Amazon.co.ukCheck price at Amazon.nlCheck price at Amazon.com.beCheck price at Amazon.frCheck price at Amazon.itCheck price at Amazon.esCheck price at Amazon.plCheck price at Amazon.seAvailable in Germany: Amazon.de
- VASNER Citara M 900 WattCheck price at Amazon.deCheck price at Amazon.co.ukCheck price at Amazon.nlCheck price at Amazon.com.beCheck price at Amazon.frCheck price at Amazon.itCheck price at Amazon.esCheck price at Amazon.plCheck price at Amazon.seAvailable in Germany: Amazon.de
- Bosch Heat Infrared 4000 P 300 WattCheck price at Amazon.deCheck price at Amazon.co.ukCheck price at Amazon.nlCheck price at Amazon.com.beCheck price at Amazon.frCheck price at Amazon.itCheck price at Amazon.esCheck price at Amazon.plCheck price at Amazon.seAvailable in Germany: Amazon.de